5-DIFF Fully Automated Hematology Analyzer BIOCELL-83

Features
- Features:
-28 Parameters, 2 Histograms, 2 Scattergrams
-60 samples/hour
-3-D Topographic Maps for WBC
-Integral Titanium Incubation System
-2 test modes & 2 sample modes
-Laser Scatter Technology
-Constant Linear Sheath Flow
-Cyanide Free reagent - QC and Calibration
Multiple QC rules, Including L-J, X-B etc
Auto and manual calibration function for both whole blood mode and pre-diluted blood mode.
- Power Supply
100V-240V, 50Hz/60Hz
- Operation environment
Temperature: 15°C -30°C
Humidity: 30%-85%
- Weight: 50KG
- Dimension: 46cm(L)x57cm(w)x61cm(H)
Technical Specifications
Technical Specification:
- Technology
3-D Topographic Map
Integral titanium incubation system
Laser Scatter technology
Flow Cytometry technology
Cyanide free reagents
- Parameters
Regular Parameters:
WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, PDW, MPV, PCT, P-LCR, NEU#, NEU%, LYM#, LYM%, MON#, MON%, EOS#, EOS%, BAS#, BAS%
Research Parameters:
ALY#, ALY%, IG#, IG%, 2 histograms, 2 scattergrams
Test Speed
60 seconds /Test
- Performance
Automated Hematology Analyzer BIOCELL-140

Features
- Features:
-20 Parameters, 3 Histograms
-3 part differentiation of WBC
-60 samples/hour
-2 counting modes: whole blood & pre-diluted
-10.4″ TFT colourful LCD with touch screen
-Built-in thermal printer, optional external printer
-External AC adapter avoids electronic noises, enhancing accuracy
-Up to 50,000 sample results ( including histograms) can be stored
-Original factory’s blood control & calibrator
- QC and Calibration
Multiple QC rules, Including L-J, X-B etc
Auto and manual calibration function for both whole blood mode and pre-diluted blood mode.
- Power Supply
AC 110V – 220V, 50/60Hz
- Operation environment
Temperature: 15°C -30°C
Humidity: 30%-85%
Technical Specifications
Test principle : Electrical resistance for counting and SFT method for HGB
Parameters : WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, PDW, MPV, PCT, P-LCR, NEU#, NEU%, LYM#, LYM%, MID#, MID% and histogram for WBC, RBC & PLT
Test Flow : Fully Auto and the blood unrequired dilute or other process
Quantity Technology : Ultra sound quantity method, resistance from disturb
Clot Clear : High voltage burn and high pressure flush
Sample Mode : Venous, Capillary and prediluted blood
Sample Volume : 20μL: whole blood 9.8μL
Language : English, Germany, Spanish, France, Portuguese
QC mode : X, X-R, X-B, L-J, auto draw and print QC gure
Calibration Mode : Auto mode and manual mode are selectable, provide
original calibrator and control
Reference Range Type : Newborn, children, male, female and universal
Reagent : Provide original reagent
Memory : Save more than 50,000 sample’s detail results including histograms
Display : 10.4″ TFT colourful LCD with touch screen, show all parameter and histograms at same screen
Printer : Inner thermal printer, canbe connected to external computer and printer
Dimension : 436mm x 363mm x 367mm (L x W x H)
Net Weight : 18 kg
Fully Automated Hematology Analyzer BIOCELL-100

Features
- Performance
Item Precision, CV
WBC < 2.0%
RBC < 1.9%
HGB < 1.9 %
MCV < 0.4%
PLT < 4.0%
Carry over WBC 2.0%, RBC 1.0%,HGB 2.0%, PLT 2.0% - Test Parameter
WBC Lymph# Mid# Gran# Lymph% Mid% Gran% RBC HGB HCT
MCV MCH MCHC RDW-SD RDW-CV PLT MPV PDW PCT P-LCR
WBC Histogram
RBC Histogram
PLT Histogram - Technical Parameter
Sample volume: Normal mode : 9.8 ul, dilution mode : 20 ul
Aperture diameter : 70u m, 100u m
Throughput : 35/60 samples/hour
Clot clear : high voltage burn and high pressure ush
Calibration Mode : Auto mode and manual mode are selectable, provide original
calibrator and control
QC mode : X, X-R, X-B, L-J, auto draw and print QC gure
Display : Large colour touchscreen, show all parameter and histograms at same screen
Memory : Save more than 30000 sample’s detail results including histograms
Input and output : Keyboard, mouse, Parallel Port, RS232 serial, can be connected with computer
Printer : Inner thermal printer, can be connected to external computer and printer
Technical Specifications
Test principle : Electrical resistance for counting and SFT method for HGB
Test Flow : Fully Auto and the blood unrequired dilute or other process
Quantity Technology : Ultra sound quantity method, resistance from disturb
Clot Clear : High voltage burn and high pressure ush
Parameter : 3 part dierentitation of WBC, 20 parameters + histograms
Sample Mode : Venous, Capillary and prediluted blood
Language : English, Germany, Spanish, France, Portuguese
QC mode : X, X-R, X-B, L-J, auto draw and print QC gure
Calibration Mode : Auto mode and manual mode are selectable, provide
original calibrator and control
Reference Range Type : Newborn, children, male, female and universal
Reagent : Provide original reagent
Memory : Save more than 30000 sample’s detail results including histograms
Display : Large colour touch screen, show all parameter and histograms at same screen
Printer : Inner thermal printer, canbe connected to external computer and printer
Working Environment : at room temperature
Voltage : AC 175V – 265V, Auto adaption according to the input voltage
Dimension : 565mm x 467mm x 571mm (L x W x H)
Net Weight : 27 kg