Auto Hematology Analyzers

5-DIFF Fully Automated Hematology Analyzer BIOCELL-83

biogengmbh

Features

  • Features:
    -28 Parameters, 2 Histograms, 2 Scattergrams
    -60 samples/hour
    -3-D Topographic Maps for WBC
    -Integral Titanium Incubation System
    -2 test modes & 2 sample modes
    -Laser Scatter Technology
    -Constant Linear Sheath Flow
    -Cyanide Free reagent
  • QC and Calibration 

Multiple QC  rules, Including L-J, X-B etc

Auto and manual calibration function for both whole blood mode and pre-diluted blood mode.

  • Power Supply 

100V-240V, 50Hz/60Hz

  • Operation environment

Temperature:   15°C -30°C

Humidity:         30%-85%

  • Weight:              50KG
  • Dimension:        46cm(L)x57cm(w)x61cm(H)

 

 

Technical Specifications

Technical Specification:   

  • Technology

3-D Topographic Map

Integral titanium incubation system

Laser Scatter technology

Flow Cytometry technology

Cyanide free reagents

  • Parameters  

Regular Parameters:

WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, PDW, MPV, PCT, P-LCR, NEU#, NEU%, LYM#, LYM%, MON#, MON%, EOS#, EOS%, BAS#, BAS%

Research Parameters:

ALY#, ALY%, IG#, IG%,   2 histograms, 2 scattergrams

Test Speed

60 seconds /Test

  • Performance

biogengmbh

Automated Hematology Analyzer BIOCELL-140

Automated Hematology Analyzer BIOCELL-140

Features

  • Features:
    -20 Parameters, 3 Histograms
    -3 part differentiation of WBC
    -60 samples/hour
    -2 counting modes: whole blood & pre-diluted
    -10.4″ TFT colourful LCD with touch screen
    -Built-in thermal printer, optional external printer
    -External AC adapter avoids electronic noises, enhancing accuracy
    -Up to 50,000 sample results ( including histograms) can be stored
    -Original factory’s blood control & calibrator
  • QC and Calibration 

Multiple QC  rules, Including L-J, X-B etc

Auto and manual calibration function for both whole blood mode and pre-diluted blood mode.

  • Power Supply 

AC 110V – 220V, 50/60Hz

  • Operation environment

Temperature:   15°C -30°C

Humidity:         30%-85%

 

Technical Specifications

Test principle : Electrical resistance for counting and SFT method for HGB

Parameters : WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, PDW, MPV, PCT, P-LCR, NEU#, NEU%, LYM#, LYM%, MID#, MID% and histogram for WBC, RBC & PLT

Test Flow : Fully Auto and the blood unrequired dilute or other process
Quantity Technology : Ultra sound quantity method, resistance from disturb
Clot Clear : High voltage burn and high pressure flush
Sample Mode : Venous, Capillary and prediluted blood
Sample Volume : 20μL: whole blood 9.8μL
Language : English, Germany, Spanish, France, Portuguese
QC mode : X, X-R, X-B, L-J, auto draw and print QC gure
Calibration Mode : Auto mode and manual mode are selectable, provide
original calibrator and control
Reference Range Type : Newborn, children, male, female and universal
Reagent : Provide original reagent
Memory : Save more than 50,000 sample’s detail results including histograms
Display : 10.4″ TFT colourful LCD with touch screen, show all parameter and histograms at same screen
Printer : Inner thermal printer, canbe connected to external computer and printer
Dimension : 436mm x 363mm x 367mm (L x W x H)
Net Weight : 18 kg

Fully Automated Hematology Analyzer BIOCELL-100

biogengmbh

Features

  1. Performance
    Item Precision, CV
    WBC < 2.0%
    RBC < 1.9%
    HGB < 1.9 %
    MCV < 0.4%
    PLT < 4.0%
    Carry over WBC 2.0%, RBC 1.0%,HGB 2.0%, PLT 2.0%
  2. Test Parameter
    WBC Lymph# Mid# Gran# Lymph% Mid% Gran% RBC HGB HCT
    MCV MCH MCHC RDW-SD RDW-CV PLT MPV PDW PCT P-LCR
    WBC Histogram
    RBC Histogram
    PLT Histogram
  3. Technical Parameter
    Sample volume: Normal mode : 9.8 ul, dilution mode : 20 ul
    Aperture diameter : 70u m, 100u m
    Throughput : 35/60 samples/hour
    Clot clear : high voltage burn and high pressure ush
    Calibration Mode : Auto mode and manual mode are selectable, provide original
    calibrator and control
    QC mode : X, X-R, X-B, L-J, auto draw and print QC gure
    Display : Large colour touchscreen, show all parameter and histograms at same screen
    Memory : Save more than 30000 sample’s detail results including histograms
    Input and output : Keyboard, mouse, Parallel Port, RS232 serial, can be connected with computer
    Printer : Inner thermal printer, can be connected to external computer and printer

Technical Specifications

Test principle : Electrical resistance for counting and SFT method for HGB
Test Flow : Fully Auto and the blood unrequired dilute or other process
Quantity Technology : Ultra sound quantity method, resistance from disturb
Clot Clear : High voltage burn and high pressure ush
Parameter : 3 part dierentitation of WBC, 20 parameters + histograms
Sample Mode : Venous, Capillary and prediluted blood
Language : English, Germany, Spanish, France, Portuguese
QC mode : X, X-R, X-B, L-J, auto draw and print QC gure
Calibration Mode : Auto mode and manual mode are selectable, provide
original calibrator and control
Reference Range Type : Newborn, children, male, female and universal
Reagent : Provide original reagent
Memory : Save more than 30000 sample’s detail results including histograms
Display : Large colour touch screen, show all parameter and histograms at same screen
Printer : Inner thermal printer, canbe connected to external computer and printer
Working Environment : at room temperature
Voltage : AC 175V – 265V, Auto adaption according to the input voltage
Dimension : 565mm x 467mm x 571mm (L x W x H)
Net Weight : 27 kg